RIB® Dry Contact Input Relay RIBM02ZNDC Panel 4"" x 2.875"" 208-277VAC 30A DPDT

Category Relays
B1034388

RIB® Dry Contact Input Relay RIBM02ZNDC Panel 4"" x 2.875"" 208-277VAC 30A DPDT

Item Code: B1034388
Category Relays
Manufacturer Functional Devices

Description

THE DRY CONTACT INPUT RIB SERIES OFFERS ALL THE ADVANTAGES OF THE STANDARD RIB LINE; PLUS IT CAN BE ACTIVATED BY A WIDE RANGE OF DRY-CONTACTS SUCH AS THERMOSTATS SWITCHES OTHER RELAYS SOLID-STATE SWITCHES ETC. THE DRY CONTACT INPUT RIB PROVIDES THE LOW-VOLTAGE (CLASS 2) POWER NEEDED TO ACTIVATE THE RELAY (SELF-POWERED) - JUST CLOSE THE DRY-CONTACT INPUT. THE POWER TO ENERGIZE THE RELAY CAN BE BROUGHT TO THE RELAY ON A SEPARATE PAIR OF WIRES ALONG WITH THE CONTROL OUTPUT OF THE CONTROLLER OR CAN BE A LOCAL POWER SOURCE NEAR THE RELAY. THE RELAY CONTACTS ARE ISOLATED FROM THE INPUT POWER AND THE DRY CONTACT INPUT; THUS THEY CAN BE WIRED TO SWITCH ANY OTHER POWER-LOAD OR LOW-VOLTAGE LOAD (SEE SPECIFICATIONS FOR CONTACT RATINGS). ONE MODEL CAN BE USED FOR MANY INSTALLATIONS (MODEL RIB21CDC CAN OPERATE FROM ANY VOLTAGE FROM 120VAC - 277VAC; SEE SPECIFICATIONS FOR THE INPUT POWER OF OTHER MODELS).

Specifications

UNSPSC Code

39122300

Weight

0.36lb

Height

1.75in

Width

4in

Length

2.88in

Brand

Functional Devices

Category

Relays

Call for price
Compare

RIB® Dry Contact Input Relay RIBM02ZNDC Panel 4"" x 2.875"" 208-277VAC 30A DPDT

Category Relays
B1034388

RIB® Dry Contact Input Relay RIBM02ZNDC Panel 4"" x 2.875"" 208-277VAC 30A DPDT

Item Code: B1034388
Category Relays
Manufacturer Functional Devices

Description

THE DRY CONTACT INPUT RIB SERIES OFFERS ALL THE ADVANTAGES OF THE STANDARD RIB LINE; PLUS IT CAN BE ACTIVATED BY A WIDE RANGE OF DRY-CONTACTS SUCH AS THERMOSTATS SWITCHES OTHER RELAYS SOLID-STATE SWITCHES ETC. THE DRY CONTACT INPUT RIB PROVIDES THE LOW-VOLTAGE (CLASS 2) POWER NEEDED TO ACTIVATE THE RELAY (SELF-POWERED) - JUST CLOSE THE DRY-CONTACT INPUT. THE POWER TO ENERGIZE THE RELAY CAN BE BROUGHT TO THE RELAY ON A SEPARATE PAIR OF WIRES ALONG WITH THE CONTROL OUTPUT OF THE CONTROLLER OR CAN BE A LOCAL POWER SOURCE NEAR THE RELAY. THE RELAY CONTACTS ARE ISOLATED FROM THE INPUT POWER AND THE DRY CONTACT INPUT; THUS THEY CAN BE WIRED TO SWITCH ANY OTHER POWER-LOAD OR LOW-VOLTAGE LOAD (SEE SPECIFICATIONS FOR CONTACT RATINGS). ONE MODEL CAN BE USED FOR MANY INSTALLATIONS (MODEL RIB21CDC CAN OPERATE FROM ANY VOLTAGE FROM 120VAC - 277VAC; SEE SPECIFICATIONS FOR THE INPUT POWER OF OTHER MODELS).

Specifications

UNSPSC Code

39122300

Weight

0.36lb

Height

1.75in

Width

4in

Length

2.88in

Brand

Functional Devices

Category

Relays

Call for price
Compare
SEARCH ×